Hyperspectral imaging in pharmaceutical manufacturing
Chemical imaging for blend uniformity, API distribution, coating, counterfeit detection and packaging verification, aligned with process analytical technology (PAT).
See the distribution, not just the average
NIR point spectroscopy gives an average. Chemical imaging shows where the API, excipients and moisture are in a tablet, blend or coating. That’s why it has long been studied for pharma process monitoring and quality control (Gowen et al., 2008; Amigo, 2010).
- Blend homogeneity and API distribution
- Coating thickness and uniformity
- Counterfeit and substandard product screening
- Packaging: correct tablet in the correct blister
How it’s deployed
At-line chemical imaging
Benchtop scanning of tablets, blisters and powder samples.
In-line PAT
Camera over a conveyor or packaging line, with real-time pass/fail.
Authentication
Spectral library comparison of suspected counterfeits.
Evidence from published research
Selected findings from peer-reviewed studies. Full citations are below.
| Application | Finding | Source |
|---|---|---|
| Process monitoring & QC | Review of chemical imaging for blending, coating and tablet QC | Gowen et al., EJPB 2008 |
| Solid dosage forms | Practical guide to HSI analysis of tablets: preprocessing, models, pitfalls | Amigo, Anal. Bioanal. Chem. 2010 |
| Counterfeit drugs | Two NIR imaging systems compared, including a spectrograph for moving tablets on a conveyor | Arnold et al., Proc. SPIE 2011 |
| Antimalarial counterfeits | Raman hyperspectral imaging quantified APIs non-invasively in tablets | Frosch et al., Molecules 2019 |
Homogeneity in minutes, not days
We’ve run hyperspectral trials on dry powder blends, such as a 3-in-1 coffee mix, to map ingredient distribution. The same approach applies to pharmaceutical and nutraceutical blends.
Recommended Headwall sensors
HELIOS EC64 / EQ32
Headwall cites inspection through opaque packaging to confirm the correct drug and dosage.
View in product range →BlueEye Gen2 UV
220–380 nm, sensitive to conjugated systems common in APIs.
View in product range →Micro-Hyperspec VNIR E-Series
High-resolution VNIR for tablets and coatings.
View in product range →References & further reading
Peer-reviewed sources. Where a study used a specific sensor, it’s noted as reported by the authors.
Pharmaceutical
| # | Reference |
|---|---|
| 1 | Gowen, A.A., O’Donnell, C.P., Cullen, P.J., Bell, S.E.J. (2008). Recent applications of chemical imaging to pharmaceutical process monitoring and quality control. European Journal of Pharmaceutics and Biopharmaceutics 69(1):10–22. 10.1016/j.ejpb.2007.10.013 Review |
| 2 | Amigo, J.M. (2010). Practical issues of hyperspectral imaging analysis of solid dosage forms. Analytical and Bioanalytical Chemistry 398:93–109. 10.1007/s00216-010-3828-z |
| 3 | Arnold, T., De Biasio, M., Leitner, R. (2011). Near-infrared imaging spectroscopy for counterfeit drug detection. Proc. SPIE 8032, 80320Y. 10.1117/12.884732 |
| 4 | Frosch, T. et al. (2019). Counterfeit and substandard test of the antimalarial tablet Riamet® by means of Raman hyperspectral multicomponent analysis. Molecules 24(18):3229. 10.3390/molecules24183229 Raman hyperspectral |
Methods
| # | Reference |
|---|---|
| 1 | Amigo, J.M., Babamoradi, H., Elcoroaristizabal, S. (2015). Hyperspectral image analysis. A tutorial. Analytica Chimica Acta 896:34–51. 10.1016/j.aca.2015.09.030 |
| 2 | Rinnan, Å., van den Berg, F., Engelsen, S.B. (2009). Review of the most common pre-processing techniques for near-infrared spectra. TrAC Trends in Analytical Chemistry 28(10):1201–1222. 10.1016/j.trac.2009.07.007 |
Continue exploring the Hyperspectral Hub
Talk to a Headwall integration partner
As an official Headwall Photonics integration partner, we specify, integrate and support Headwall hyperspectral systems, from lab feasibility to full production lines. Send us samples and we’ll show you what the data can do.
- Feasibility trials on your samples
- Headwall sensor selection and integration
- Real-time classification wired into your line
Start a conversation
Email sales@automateandcontrol.co.uk or call +44 208 1333 585. Send a sample, a photo or a spec, and we’ll take it from there.
Contact our engineersHeadwall product range