Functional safety & Performance Level compliance
We design, upgrade and project-manage control systems with safety built in from the first line of the risk assessment. Everything is designed around SISTEMA and EN ISO 13849-1, and validated with certified functional safety partners.

Safety isn’t bolted on at the end. It’s designed in from day one.
From concept and risk assessment through panel design, PLC and safety-PLC programming, installation, validation and handover, we manage the project as one accountable process. Every safety function is defined, calculated and documented before a single cabinet is wired.
Built around a SISTEMA-first philosophy
Risk assessment
Hazards identified and required Performance Level (PLr) set for each safety function, to EN ISO 12100 and EN ISO 13849-1.
Architecture & design
Control and safety architecture (category, redundancy and diagnostics) chosen to meet PLr.
SISTEMA modelling
Every safety function modelled in SISTEMA: MTTFd, DCavg, CCF, and achieved PL compared with PLr.
Build, validate & handover
Safety PLC programming, wiring, validation to EN ISO 13849-2, and a full safety report.
Upgrading the safety performance of existing machines
Older machines often predate current standards, or were modified without re-verification. We bring them up to date without replacing the whole machine.
- PL gap analysis of the existing safety functions
- Upgrade path: safety PLC, safety relays, interlocks, light curtains, STO drives
- Re-verification in SISTEMA after modification
- Sign-off and documentation for your technical file
| Safety function | Typical PLr | Typical solution |
|---|---|---|
| Emergency stop | PL d | Dual-channel e-stop to safety PLC, STO |
| Interlocked guard | PL d | Coded interlock switches, monitored |
| Light curtain muting | PL c–d | Type 4 curtain with safety PLC logic |
| Over-travel (hoists) | PL d | Independent limit or safety-rated encoder |
| Two-hand / enabling | PL c–d | Monitored enabling device |
Typical values only. PLr is always set by your own risk assessment.
Related solutions
Need a PL gap analysis or SISTEMA verification?
Send us your machine details and any existing risk assessment. We’ll tell you where you stand and what it takes to close the gap.
Start a conversation
Email sales@automateandcontrol.co.uk or call +44 208 1333 585. Send a sample, a photo or a spec, and we’ll take it from there.
Contact our engineers