Functional Safety & Performance Level (PL) Compliance

Home / Machine control / Functional safety
Functional safety

Functional safety & Performance Level compliance

We design, upgrade and project-manage control systems with safety built in from the first line of the risk assessment. Everything is designed around SISTEMA and EN ISO 13849-1, and validated with certified functional safety partners.

EN ISO 13849SISTEMAEN ISO 12100IEC 62061 aware
Functional safety &amp; <em>Performance Level</em> compliance
Our approach

Safety isn’t bolted on at the end. It’s designed in from day one.

From concept and risk assessment through panel design, PLC and safety-PLC programming, installation, validation and handover, we manage the project as one accountable process. Every safety function is defined, calculated and documented before a single cabinet is wired.

1Risk assessmentEN ISO 12100 ·PLr2ArchitectureCategory · MTTFd· DC3SISTEMAPL achieved ≥PLr4Build & codeSafety PLC ·wiring5ValidateEN ISO 13849-26HandoverReport · techfile
What we deliver

Built around a SISTEMA-first philosophy

Risk assessment

Hazards identified and required Performance Level (PLr) set for each safety function, to EN ISO 12100 and EN ISO 13849-1.

Architecture & design

Control and safety architecture (category, redundancy and diagnostics) chosen to meet PLr.

SISTEMA modelling

Every safety function modelled in SISTEMA: MTTFd, DCavg, CCF, and achieved PL compared with PLr.

Build, validate & handover

Safety PLC programming, wiring, validation to EN ISO 13849-2, and a full safety report.

Existing machinery

Upgrading the safety performance of existing machines

Older machines often predate current standards, or were modified without re-verification. We bring them up to date without replacing the whole machine.

  • PL gap analysis of the existing safety functions
  • Upgrade path: safety PLC, safety relays, interlocks, light curtains, STO drives
  • Re-verification in SISTEMA after modification
  • Sign-off and documentation for your technical file
Safety functionTypical PLrTypical solution
Emergency stopPL dDual-channel e-stop to safety PLC, STO
Interlocked guardPL dCoded interlock switches, monitored
Light curtain mutingPL c–dType 4 curtain with safety PLC logic
Over-travel (hoists)PL dIndependent limit or safety-rated encoder
Two-hand / enablingPL c–dMonitored enabling device

Typical values only. PLr is always set by your own risk assessment.

Next step

Need a PL gap analysis or SISTEMA verification?

Send us your machine details and any existing risk assessment. We’ll tell you where you stand and what it takes to close the gap.

Start a conversation

Email sales@automateandcontrol.co.uk or call +44 208 1333 585. Send a sample, a photo or a spec, and we’ll take it from there.